Start from the setting and the standard, then choose the luminaire: indoor halls, outdoor courts and auxiliary spaces need different fixtures, and the calculation confirms each choice.
LED high bay lights are the usual starting point over an indoor court. The UFO high bay, for example, runs from 100W to 320W with 60°, 90° or 120° optics and an IK10 housing. The layout keeps fixtures out of the zone players look into when they shoot.
Some halls add wall or truss mounted floodlights along the sides to raise vertical light on the players. Their position and aiming are set in the calculation so they stay out of the players' sightlines and the camera's view.
Panel lights suit changing rooms, corridors, offices and rest areas around the court, where lower light levels apply. They are not the luminaire for the playing area.
Halls shared with volleyball, badminton or events often run several lighting scenes on one installation. The control system and the calculation need a scene for each sport and use.
For full size outdoor courts, the RG Series 500W and 600W models are the sizes GS LIGHT lists for basketball and tennis courts, with 8° to 60° optics and IP66.
All in two solar street lights can light a recreational court without a grid connection. Suitability depends on the site's solar resource and shading, the evening operating and dimming profile, battery capacity and seasonal autonomy, and a calculation against the target light level. They are not a competition lighting system.
A single outdoor court is often lit with flood lights on poles along the sidelines or at the corners. GS LIGHT's stadium floodlights run from 200W to 800W with 30°, 60° or 90° beams, IP65 and IK08.
High mast lighting suits parks where several courts sit side by side and a few tall masts can replace many short poles. For a single court, poles closer to the court usually give better control of aiming and spill light.
The required light level depends on which framework the venue must meet: EN 12193 for general play and national competition in Europe and many export markets, FIBA's rules for FIBA official competitions, and ANSI/IES RP-6 in North America.
EN 12193:2018 gives maintained average horizontal illuminance on the court's reference area, and uniformity (Uo) as the minimum divided by the average. FIBA's rules give their own values for horizontal, vertical and main camera illuminance and use two ratios, minimum to average and minimum to maximum. The source is FIBA's Official Basketball Rules 2026: Basketball Equipment, section 12.
Outdoors, EN 12193 limits glare with a glare rating (GR) set for each class. Indoors, glare is controlled mainly by where the luminaires sit and how they are aimed relative to the players' sightlines, especially when they look up at the basket. Reflections from a glossy floor also matter, and for televised games FIBA requires that no reflected light is visible from the main camera position. The applicable method and limits come from the standard and edition named for the project.
For FIBA official competitions, FIBA requires a color rendering index of at least Ra 80 and a color temperature of 4,000K to 6,000K, held within 500K of the average. Other venues follow the project specification, and broadcasters may ask for more. GS LIGHT offers CRI and color temperature options per model.
FIBA sets a flicker factor of 1% or less for its official competitions, because flicker shows up in slow motion replays. For other venues, ask for the flicker figure of the exact model and driver quoted, measured against the camera frame rates that will be used.
Indoor courts usually need a modest ingress rating, and outdoor courts need IP65 or higher against rain and dust. Every fixture over an indoor court also needs ball impact protection. An IK rating on the housing does not prove this; ask for a ball impact test of the complete luminaire, guard and mounting, such as DIN 18032-3.
GS LIGHT quotes every luminaire below with the available technical documents for the model. GS LIGHT's company profile lists an in house lab with a photometric darkroom, integrating sphere, IK impact, waterproof and aging tests; ask which tests were run on the model quoted. Certificate details are on our certifications page and are supplied per model.
Brochures for the stadium and high bay ranges are in our downloads library.
This is an illustrative scenario, not a guaranteed saving: it assumes the LED layout meets the same maintained illuminance, uniformity and glare targets, which a photometric calculation must confirm.
A 400W LED floodlight does not always replace a 1,000W metal halide lamp; the calculation decides the wattage. The result changes with the existing system's measured draw, the operating hours and the tariff, and it leaves out dimming and maintenance. Rated life is stated on each model's datasheet with its test conditions.
There is no single height: indoors the mounting height follows the roof structure and the calculation, and outdoors the pole height comes from the layout. Keep it apart from clear height, the free space above the court, which FIBA's 2026 equipment rules set at a minimum of 7 m for FIBA official competitions. The calculation then sets the aiming for each fixture at the chosen height.
Place and aim the luminaires so they stay out of the players' sightlines, especially when they look up at the basket, and check reflections from the floor toward any camera position. Ask which glare control accessories are available for the model quoted; accessories change the light output and distribution, so the calculation must include them.
There is no single best value: FIBA official competitions require 4,000K to 6,000K held within 500K of the average, and other courts follow the project specification. Hold one color temperature across the court so players and cameras see consistent white light. GS LIGHT models offer color temperatures from 3000K to 6500K depending on the series.
Uniformity measures how evenly light falls on the court; EN 12193 expresses it as the minimum divided by the average illuminance on the reference area. EN 12193:2018 sets values of about 0.5 to 0.7 depending on the class, and FIBA uses both minimum to average and minimum to maximum ratios for its competitions. Poor uniformity creates dark patches that make the ball harder to follow and camera exposure harder to set.
FIBA's lighting requirements are in section 12 of its Official Basketball Rules, Basketball Equipment, and apply to FIBA official competitions. The 2026 edition sets maintained horizontal illuminance of 1,500 to 3,000 lux, vertical illuminance of 1,700 lux and 2,000 lux toward the main camera on the 19 × 32 m principal playing area. It also sets uniformity ratios, a flicker factor of 1% or less, Ra 80 or higher and 4,000K to 6,000K. Confirm the edition that applies to the event, and check any product's approval status directly with FIBA.
GS LIGHT recommends suitable luminaires and provides a product quotation with the available technical documents. Lighting design, structural checks, electrical design and installation stay with the project's appointed professionals.
Tell us the court dimensions, indoor or outdoor location, mounting details, level of play and timing. We reply with a luminaire recommendation, a product quotation and the available technical documents.